GCT's test site is located in Prairieville, Louisiana is located on an ideal piece of property situated in a neighborhood of approximately 450 homes, and is completely fenced with a 10 foot privacy fence for security. The site is located approximately five miles down Interstate 10 from our Baton Rouge office.
The GCT dosing system is a state of the art computer driven system. GCT utilizes four Siemens controllers to dose the aerobic treatment units pursuant to the Standard. Additionally, we have a dual grinder pump system for the neighborhood only influent wet well for redundancy in our operations.
Raw wastewater is pumped wet well fed by a neighborhood subdivision to an influent tank located on our testing facility by the grinder pumps. Dosing pumps located within the influent tank feed the raw influent through a manifold and valve system to each aerobic treatment unit at five gallon increments until the correct dose is administered pursuant to Standard. The entire valve system is operated by four Siemen controllers for accuracy and reliability.
We also perform all equipment evaluations pursuant to Standard 46 and Standard 385 at the Prairieville test site.